When a mall’s planning team starts on Chinese New Year mall decorations, the usual mistake is to pick a theme first and then look for places to put it. The order should be reversed: look at what each position has to do — pull people in, or set the mood — and only then decide what goes there and how big it should be. The eight positions below are the ones most malls actually have, each with sizing rules you can apply directly: not “make it feel grand”, but how much clear height, how far apart, and whether people can see the top.

01 Mall entrance and arch — will anyone come in?

The entrance answers one question: from across the road, can someone tell that this mall has done something for the New Year?

Start with clear height. The bottom edge of the entrance piece should not sit below 3 metres — people have to pass underneath, and the escape route has to stay clear. Many schemes are sent back by mall management for exactly this: it looks good, but it does not meet the requirement, or it blocks the escape route.

Width does not need a formula. Take the actual opening and extend 1 to 1.5 metres to each side, so the piece visually wraps the entrance. Indoor malls often run the entrance straight into the walkway behind it, using New Year passageway lanterns so there is something to look at from the door to the atrium.

Phoenix lantern perched on a flower lantern archway above a luxury boutique entrance at night

02 Atrium centrepiece — the only place that can go large

The atrium is the only spot where a big piece works, and it is the visual centre of the whole mall.

Height: the piece should take up 50 to 65 per cent of the atrium’s clear height. Below half it cannot hold the space; above two-thirds, standing on the ground floor you cannot see the top — what visitors get is a piece cut off at the top.

Easier to miss than height is the viewing angle. The deeper the atrium, the more the piece has to come down. In the same building, an atrium with 15 metres of clear height and one with 25 metres need different centrepiece heights, because the visitor’s position has not changed but the upward angle has. For seasonal sets on the same footprint, it is worth reading how the mid-autumn mall decoration ideas were laid out.

Lanterns Suspended Over a Mall Atrium at New Year

03 Escalators and corridors — will people keep going up?

The goal here is simple: get people from the ground floor to the top, with something to look at on every level.

Space the visual nodes every 8 to 12 metres. Comfortable viewing height sits between 1.5 and 2.2 metres — below that people look down, above it they look up, and neither feels natural.

The most common mistake is hanging the same piece all the way up. It works on the first sight and goes numb by the third floor. One change per group beats filling every metre. Where the corridor already has a wall scheme, coordinate the two rather than stacking on top of it — see our mall wall lighting designs.

04 Window displays — different sizing logic from the atrium

Windows are what retail brands care about most, and where the requirements are tightest. They are also where Chinese New Year mall decorations are seen from closest.

A typical window is 1 to 1.5 metres deep, with a viewing distance of 2 to 3 metres. Put the piece’s height baseline about 20 centimetres above the middle of the glass, so the eye lands on the body of the piece.

The usual error is to scale an atrium piece down and drop it into a window. The viewing distance goes from a dozen metres to two, and the small version turns into a toy.

Giant indoor floral decorative lantern sculpture with orange blooms and flying birds

05 Overhead hanging — cheapest and fastest way to lift the mood

The layer above eye level is the most overlooked part of Chinese New Year mall decorations, and it is the best value in the building.

Hang so the bottom edge clears 2.5 metres, and keep a safe distance from sprinkler heads and light fittings. This has to be worked into the layout from the start, not discovered during approval.

There is also an indoor problem worth planning for: atriums have air movement. Light hanging pieces rotate slowly, and once they turn, the pattern breaks up.

Pink peony hanging lantern installation decorating a multi-floor shopping mall atrium with shoppers below

06 Photo spot — will it get photographed and shared?

The goal is specific: people step in, take the shot, and want to post it.

The rule is clearance. Leave room for two or three people to stand, and check that a camera three to four metres back can still fit both the people and the piece. Many Chinese New Year mall decorations are packed so full that they look spectacular in person and cannot be photographed — the frame ends up with half a person and a wall of detail. Mark the standing position on the floor and take one phone shot before signing off.

Gift box flower lantern display on traditional building with pink bow and blue floral swirls

07 Family zone — how long people stay

Families with children stop here for an extra 15 to 20 minutes, and those 20 minutes decide the food and retail takings on that floor.

The rule is eye height. A child standing there has their eyes at roughly 1.1 to 1.3 metres, so anything meant to be read by a child has to sit at that height — not at 1.6 metres and above, where an adult’s eye line is. Built to adult eye level, the result is predictable: adults think it looks good, and children see the base and the supports. Animal forms carry this zone best; see the animal lantern decorations used in mall work.

08 Outdoor plaza and car park approach — the first judgement for drivers

For anyone arriving by car, the judgement “has this mall done Chinese New Year mall decorations this year” is made in the few seconds at the car park entrance or on the plaza.

The same form has to be 1.5 to 2 times larger outdoors to read the same, because outdoor viewing starts from 30 metres away. Move an indoor size outside unchanged and all that is left at distance is an outline.

Orientation matters too: face the direction cars mainly arrive from, not the building’s front elevation.

Fish lantern sculpture display of leaping orange fish and glowing egg-shaped lanterns at a luxury shopping mall plaza

These eight positions have no standard answer

The order that actually matters is only three steps: what should this position make people do, how big does the piece therefore need to be, and does the building limit it — clear height, escape routes, sprinklers, air movement.

Once those three are done, the dimensions mostly fall out. Start with a theme and then look for somewhere to put it, and you end up with “great theme, but it does not fit anywhere”.

Next in this series: how to settle the theme for Chinese New Year mall decorations. The full lantern range sits on our festival lanterns page if you want to see what the zones end up looking like.

Frequently asked questions

How far ahead should a mall book Chinese New Year decorations?
Most malls lock the design three to four months before the season and come on site four to six weeks ahead. Booking after December usually means choosing from existing sets rather than a custom build.

How tall should an atrium centrepiece be?
Half to two thirds of the atrium’s clear height. Below half it cannot hold the space; above two thirds you cannot see the top from the ground floor.

Can the same set be used again next year?
Yes, if it was built in modules. A set can be re-sequenced into a different atrium or a different floor, and the theme can be refreshed without rebuilding every piece.

Is there a difference between Lunar New Year and Chinese New Year?
They name the same festival. Malls in North America and parts of Europe usually say Lunar New Year; clients in Asia and the UK more often say Chinese New Year. The display is the same.

What does a mall need to send for a quote?
Floor plans with clear heights for each zone, peak footfall, and the dates the display has to be up and down. With those three we can return a zone-by-zone layout and a piece count. The main input, though, is what kind of theme you want — that is where custom lantern solutions start.

How are fire and escape requirements handled?
Every zone has to leave the escape route clear and keep a safe distance from sprinkler heads. Give us the site plan and the layout is designed inside those limits from the first version.

Contact Us